CVE-2025-14096

HIGH
中文标题:
(暂无数据)
英文标题:
Credential Disclosure vulnerability in Radiometer Products
CVSS分数: 8.4
发布时间: 2025-12-17 12:19:27
漏洞类型: (暂无数据)
状态: PUBLISHED
数据质量分数: 0.40
数据版本: v2
漏洞描述
中文描述:

(暂无数据)

英文描述:

A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.

CWE类型:
CWE-250 CWE-798
标签:
(暂无数据)
受影响产品
厂商 产品 版本 版本范围 平台 CPE
Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers Windows 7 Operating system - - cpe:2.3:a:radiometer_medical_aps:abl90_flex_and_abl90_flex_plus_analyzers:windows_7_operating_system:*:*:*:*:*:*:*
Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers Windows XP Operating system - - cpe:2.3:a:radiometer_medical_aps:abl90_flex_and_abl90_flex_plus_analyzers:windows_xp_operating_system:*:*:*:*:*:*:*
Radiometer Medical Aps AQT90 FLEX Analyzers Windows 7 Operating system - - cpe:2.3:a:radiometer_medical_aps:aqt90_flex_analyzers:windows_7_operating_system:*:*:*:*:*:*:*
Radiometer Medical Aps AQT90 FLEX Analyzers Windows XP Operating system - - cpe:2.3:a:radiometer_medical_aps:aqt90_flex_analyzers:windows_xp_operating_system:*:*:*:*:*:*:*
Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX analyzers Windows 7 Operating system - - cpe:2.3:a:radiometer_medical_aps:abl800_basic_and_abl800_flex_analyzers:windows_7_operating_system:*:*:*:*:*:*:*
Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX analyzers Windows XP Operating system - - cpe:2.3:a:radiometer_medical_aps:abl800_basic_and_abl800_flex_analyzers:windows_xp_operating_system:*:*:*:*:*:*:*
解决方案
中文解决方案:
(暂无数据)
英文解决方案:
(暂无数据)
临时解决方案:
(暂无数据)
参考链接
无标题 OTHER
cve.org
访问
CVSS评分详情
3.1 (cna)
HIGH
8.4
CVSS向量: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
机密性
HIGH
完整性
HIGH
可用性
HIGH
时间信息
发布时间:
2025-12-17 12:19:27
修改时间:
2025-12-17 14:43:16
创建时间:
2026-01-12 02:11:06
更新时间:
2026-01-12 02:27:30
利用信息
暂无可利用代码信息
数据源详情
数据源 记录ID 版本 提取时间
CVE cve_CVE-2025-14096 2025-12-19 03:24:32 2026-01-12 02:11:06
NVD nvd_CVE-2025-14096 2025-12-19 03:25:39 2026-01-12 02:27:30
版本与语言
当前版本: v2
主要语言: EN
支持语言:
EN
安全公告
暂无安全公告信息
变更历史
v2 NVD
2026-01-12 02:27:30
data_sources: ['cve'] → ['cve', 'nvd']
查看详细变更
  • data_sources: ['cve'] -> ['cve', 'nvd']